Learn / Heat treating

Heat treating S35VN

S35VN is Crucible's powder metallurgy stainless steel, a tougher and easier-to-grind version of S30V. The tested route is hotter than the producer's own sheet and adds liquid nitrogen, so the first decision is which of the two you are following.

Knife Templates · 4 min read

Where I would start

A martensitic stainless steel, released in 2009 as a modification of S30V for superior toughness and machinability. It does not particularly excel in any one category, though it is not terrible in any of them either.

The recommended route for S35VN. The producer's data sheet describes a different route, set out in the catch below. It assumes annealed bar.

Get the equipment ready

A furnace holding about 2025°F (1107°C), quench plates, liquid nitrogen and a checked tempering oven. The article does not cover surface protection for the hold, so use the foil guidance for stainless steel.

Measure the furnace and tempering oven independently where possible. A controller display is a setpoint, not proof that the whole blade has reached it. Timing a hold starts after equalisation, not as soon as the door closes.

A process to work from

Use this as a complete route to establish on a coupon from your stock. Temperatures in Celsius are rounded conversions of the Fahrenheit setpoints. A different supplier, section or starting condition can need a different process.

S35VN: worked heat-treatment route
StageWhat to do
PrepareFinish the profile, holes and burr removal while soft. Leave measurable cleanup stock on the faces and edge.
Austenitise2025°F (1107°C) for 15 minutes. The recommended heat treatment is austenitizing for 15 minutes at 2025°F, a plate quench, a liquid nitrogen treatment for at least 30 minutes, and two 2-hour tempers between 300 and 400°F.
QuenchPlate quench.
Cold stepLiquid nitrogen, for at least 30 minutes.
Temper300 to 400°F (149 to 204°C), twice for 2 hours each. Choose the tempering temperature for the hardness you want, with the lower temperature for higher hardness. Expect at least 60 Rc along with good toughness.

The detail to pay attention to

The producer's data sheet is a different route. As Niagara Specialty Metals publishes it: preheat at 1550 to 1600°F, harden at 1900 to 2000°F for 15 to 30 minutes, quench in air or by positive pressure (2 bar minimum) to below 125°F (50°C), a freezing treatment optionally between tempers, a double temper at 400 to 750°F for at least 2 hours each, and an aim hardness of 58 to 61 HRC. The tested route is hotter than that window and tempers lower. Keep the two apart.

Run a coupon first. When another maker heat treated a set of the toughness specimens, they came out consistently about 1 Rc lower in hardness than the originals with the same heat treatment, so measure your own result and do not assume the published number.

Check the result before fitting the handle

Clean scale and decarburisation from the test surface before interpreting a hardness reading. Use a flat, supported area and a calibrated method appropriate to the sample thickness. A file skating across a blade is a rough check, not an HRC measurement.

Inspect the tempered blade in good light for cracks, edge waves and distortion. If a blade is cracked, retire it. If hardness is unexpectedly low, check the whole record before increasing temperature or repeating a quench.

Keep a record

Keep the stock supplier and batch, blade and edge thickness, furnace program, actual hold, oil or plate details, cold-treatment branch and temper cycles beside the editable design. Add measured hardness and where it was measured.

After grinding and sharpening, evaluate the finished knife in its intended cutting work. Keep notes on edge stability, sharpening and geometry. Change one main variable so you can tell what helped as you learn.

Where this comes from

  • S35VN Steel: Properties and How to Heat Treat, Knife Steel Nerds. Larrin Thomas’s tests of S35VN with datasheet comparisons. His route is hotter than the producer’s. The charts are images, so this site quotes only the text.
  • CPM S35VN data sheet, Niagara Specialty Metals. The CPM S35VN data sheet as published by a distributor of Crucible’s CPM steels; Crucible’s own copy was not reachable. Producer data, not independent testing, and a different route from Larrin Thomas’s.
Next upHeat treating CPM-154CPM-154: the equipment, hardening hold, quench, temper and details that are easy to miss.